Standard Pump Troubleshooting

 

Problem:  Dripping Tip 

A) A common cause for dripping tips is the top o-ring in the pump being worn out.  Below are two ways to check the o-ring without taking the pump apart.

  1. Without the pumps operating open the reservoir and look for bubbles.  If you see bubbles the top o-ring is bad.  The o-ring is really worn if this test is positive.

  2. Remove the stainless connector on the top of the pump.  Fill the exposed reservoir with fluid and watch for bubbles. If you see bubbles the top o-ring is bad

B) A common cause for dripping tips is the use of the wrong ferule on the plastic tubing.  The correct ferule is shaped like a funnel.  Most tool cribs have the barrel shaped ferules – these do not work. 

C) A common cause for dripping tips is a week spring or worn out check ball.  Every tip has a spring and ball with it.  Try replacing this spring and check ball.

 Questions - Call 256-830-6679 or Click Here to E-Mail Variegate, Inc.

NOTE - Lower section of menu has Technical Information page links)

Go to ... Fluid Delivery Main Page

Go to ... Accessories

Go to ... Modular Components - High Viscosity Pump, Standard Pump Cut-Away & Solenoid (buy with or without remote tank)

Go to ... Systems - One to 12 Pump (Micro-Flex, Min-Flex, ...)

Go to ... Systems - One to Two Pump Mod Flex - NEW 2003

Technical Information:

Go to ... Maintenance, Pump Information, ...

Go to ... Pump Part Identification Drawing & List

Go to ... Pump Picture - View Details via Cut-away of Standard & Micro Pump

Go to ... Tip Selection - See the spray pattern for the various tips

Go to ... Troubleshooting

THE “FLEXSPRAY” PISTON-PUMP BODY GUARANTEE:

The pistons and pump bodies on all “FlexSpray” pumps are guaranteed against failure due to cylinder bore scoring or material defects or workmanship, during normal use, for as long as the pump assembly continues to be in active service under the same application and design criterion initially intended. Upon submission of a defective piston, pump body or both, “FlexSpray” or one of its distributors will provide a replacement piston and/or pump body of the same size and specification, with out cost to the end user.

Request a Quote - Click Here

E-Mail: Click Here to E-Mail Variegate, Inc.

Voice: (256) 830-6679

Variegate, Inc. Since 1992 - 111 Grayfox Trail Huntsville, AL 35806

Copyright Variegate, Inc. 2000-2017

Variegate, Inc.'s Main Menu